Construction Phase
After the financial close/financial investment decision is achieved, projects move ahead to construction preparation and execution. Key aspects of Technical Due Diligence at this stage are:
As per realisation phase
- Layout and Design Reviews
- Technology Review
- Resource / Energy Yield Assessments
- Land Lease and Cadastral Review
- Grid Connection Review
- Planning and Environmental Review
- Site Inspections
- Construction Contracts Review
- Asset Management Contracts Review
- Tariff and PPA Review
- Reporting
Permit/License Condition Compliance
- Building Permit Condition Discharge Review
- Building Permit condition site controls review
- Environmental Permit Condition Discharge Review
- Review of license applications, e.g. grid
- Inclusion of EGS best practice in construction
- Remaining Aggregated Limitations assessment
- Detailed CAPEX/OPEX implications assessment
- Benchmarking versus international best practice
- Grid connection license application review
Forte Value: Our process combines detailed desk study and on-site review to ensure accuracy and completeness of the assessment.
Design Management Reviews
- Employers Design Management Strategy Review
- Design Review Contract Checks
- Review of 3rd party Design Checks
- Review of design certfications by 3rd party
- Benchmarking versus international best practice
- Extra service: Design review if no 3rd party checks
Quality Management Reviews
- Quality Management Master Plans review
- Inspection and testing plan Review
- Quality control checklist templates Review
- Method Statements Spot Checks
- Quality Management resourcing review
- Quality management tools/data sharing review
- Benchmarking versus international best practice
HSE Management Reviews
- Health and Safety plans reviews
- Environmental plans review
- Archeology plans Review
- EPP checklist review
- Personal security review
- Habitat Management Plans (HMP)
- Peat Management Plans (PMP)
- Contaminated land surveys analysis and mitigation
Construction Site Audit
- Site Establishment Spot-check
- Civil BOP Works Inspections
- Electrical BOP Works Inspections
- TSA Works Inspections
- Construction site compound spot-check
- Traffic Management Spot-check
- HSE Best practice Adherence Spot-checks
- Third party services and materials review
- Risks, opportunities, and mitigations Identification
Handover Planning Reviews
- BOP Punch List Reviews
- TSA Punch List review
- As built drawings Spot Checks
- Designers Quality Control reporting review
- Owners Engineer Quality Control reporting review
- Designers Statement of Compliance review
- Owners Engineer Statement of Compliance review
- Handover Certificates Review
- Schedule for clearance of final punch list items
Project Costs & Financial Model
- BOP Punch List Reviews
- TSA Punch List review
- As built drawings Spot Checks
- Designers Quality Control reporting review
- Owners Engineer Quality Control reporting review
- Designers Statement of Compliance review
- Owners Engineer Statement of Compliance review
- Handover Certificates Review
- Schedule for clearance of final punch List items
Forte Value: Our local market knowledge, value engineering principles, and strong commercial experience are trusted to perform robust analysis on all CAPEX and OPEX reviews and formulation.
Track Record
| Wind Farm Name | Client's Name | MW | WTGs | OEM | WF Phase | Service Type | Country | Continent | SC Year | COD Year |
|---|---|---|---|---|---|---|---|---|---|---|
| Deil | NTR | 8 | 2 | Vestas | C | TDD | NL | EUROPE | 2020 | 2020 |
| Weijerwold | NTR | 7 | 2 | Vestas | C | TDD | NL | EUROPE | 2020 | 2021 |
| Bijvanck | NTR | 13 | 4 | Vestas | C | TDD | NL | EUROPE | 2020 | 2021 |
| Zeewolde | NTR | 17 | 4 | Vestas | C | TDD | NL | EUROPE | 2020 | 2021 |
| Rietvelden | NTR | 11 | 3 | Nordex | C | TDD | NL | EUROPE | 2020 | 2021 |
| Koningspleij | NTR | 4 | 1 | Enercon | C | TDD | NL | EUROPE | 2020 | 2021 |
| De Veenwieken | NTR | 9 | 4 | Enercon | C | TDD | NL | EUROPE | 2020 | 2021 |
| Wieringermeer | Eurus Energy | 35 | 15 | VAR | C | TDD | NL | EUROPE | 2018 | 2014 |
| Shantavny | Brookfield | 14 | 7 | Enercon | C | TDD | UK | EUROPE | 2016 | 2017 |
| IE Hartel 2 | IE | 24 | 8 | GE | C | TDD | NL | EUROPE | 2015 | 2016 |
Case Studies
Glogow WF (TDD-A) - Poland
| Location | Żukowice district, South-East Poland | |
| Developer | EDP Renewables | |
Technology | Supplier TBC – 5 WTG – 24 MW | |
EBOP/Grid | 110/30kV WF Sub – HV Line- DSO 110kV Substation | |
Status | Permit application in 2022 (to be confirmed) | |
Services
| Development Review | Zoning Plans, Land lease Agreements, Environmental Impact | |
| Technical Analysis and Feasibility |
| |
| Financial Feasibility | CAPEX cost estimates for proposed | |
Piotrków Kujawski WF (TDD-B) - Poland
| Location | Kujawy – Pomerania voivodship, Northern Poland | |
| Developer | ERG | |
| Technology | Nordex– 7*N117 (x3.5MW) H120 – 25 MW | |
EBOP/Grid | 110/30kV WF Sub – 150m HV line – DSO 110kV Sub | |
| Status | FID Achieved in November 2020, COD in May 2022 | |
Services
| Development Review | Building Permits Environment Decisions Zoning Cadastral Check | |
| Technical Analysis and Feasibility | Grid Connection Agreement Review | |
| Financial Feasibility | Capex Evaluation | |
Shantavny WF (TDD-C) - N. Ireland
| Location | Garvaghy, Co. Tyrone | |
| Developer | Brookfield Renewable | |
| WTG Details | 7 x Enercon E70 | |
| Capacity / COD | 14 MW | |
| Status | COD Achieved in 2017 | |
Services
| Design Review CAT III (FDN) | |
| Construction Checks | |
| Due Diligence Reporting | |
| Executed Construction QA |
BVDR WFs (TDD-D) - The Netherlands
| Location | Noord Holland, The Netherlands | |
| Developer | Eurus Energy Europe | |
| WTG Details | 13 x Vestas V90 2.0, 2 x Enercon E70 | |
| Capacity / COD | 33 MW | |
| Status | COD Achieved in 2017 | |
Services
Evaluation of foundation issues in operational Wind Turbines | ||
| As-built documentation/operational documents review | ||
| Determining severity of damages in order to make warranty claim | ||
| Asset management measures identification | ||